Specifications changes for OLS, RJE/RJOR, and SMFS
A 1971 UCSB note that retires one network service and adjusts two others to match protocol changes.
White, J.E., "Specifications changes for OLS, RJE/RJOR, and SMFS", RFC 217, DOI 10.17487/RFC0217, September 1971, <https://www.rfc-editor.org/info/rfc217>.
@misc{rfc217,
series = {Request for Comments},
number = 217,
howpublished = {RFC 217},
publisher = {RFC Editor},
doi = {10.17487/RFC0217},
url = {https://www.rfc-editor.org/info/rfc217},
author = {J.E. White},
title = {{Specifications changes for OLS, RJE/RJOR, and SMFS}},
pagetotal = 2,
year = 1971,
month = sep,
} RFC text
RFC 217 8 September 71 NIC 7547 James E. White Categories: G.3 Computer Research Lab. Updates: RFC 105, RFC 122 Univ. of California Obsoletes: RFC 74 Santa Barbara Specification Changes for OLS, RJE/RJOR, and SMFS The following documents are hereby revised: (1) 'Specifications for Network Use of the UCSB On-Line System [16 October 70, RFC 74, NIC 5417], (2) 'Network Specifications for Remote Job Entry and Remote Job Output Retrieval at UCSB' [22 March 71, RFC 105, NIC 5775], and (3) 'Network Specifications for UCSB's Simple- Minded File System' [26 April 71, RFC 122, NIC 5834]. Revisions are as follows: (1) As far as can be determined, no Network site has written code to interface to the UCSB software documented in RFC 74 last October. Accordingly, UCSB has terminated support for that software, and hence RFC 74 is obsolete. (2) In accordance with subsequent Host-Host protocol changes, the notion of 'message type' has been dropped from the specifications for RJE and RJOR, RFC 105. RJE/RJOR no longer send, nor expect to receive 8 bits of zeros as the first byte trans- mitted over a connection. (3) In accordance with Document 2, RJE and RJOR now employ a standard ICP to create a full duplex connection to the user. Accordingly, RJE and RJOR listen on sockets x'201' and x'301', respectively (rather than on x'200' and x'300' as before). As documented in RFC 105, RJE required only a simplex connection to the user. A full duplex connection is now supported, but no data is transmitted to the user over the NIC 7547 added simplex connection. RJOR now also supports a full duplex connection. However, if RJOR is required to call the user back when a requested job's output is ready, it still does so employing a simplex connection to the user's receive socket. (4) RJE/RJOR and SMFS specify a byte size of eight for their connection to the user's receive socket. The user may choose the byte size for the other simplex connection to suit himself; any valid byte size is acceptable to UCSB. [ This RFC was put into machine readable form for entry ] [ into the online RFC archives by BBN Corp. under the ] [ direction of Alex McKenzie. 12/96 ]
AI ELI5
On this page
§1Three Documents Being Revised
RFC 217, written by James E. White at the University of California, Santa Barbara (UCSB), revises three earlier UCSB documents. They cover the On-Line System (OLS) in RFC 74, Remote Job Entry (RJE) and Remote Job Output Retrieval (RJOR) in RFC 105, and the Simple-Minded File System (SMFS) in RFC 122.
The note is dated 8 September 1971 and lists four numbered revisions.
It is a short note saying which of three old instruction sheets are out of date and what to change in them.
§2The Four Revisions
First, no network site is known to have written code for the OLS software documented in RFC 74. UCSB therefore stopped supporting it, and RFC 74 is declared obsolete.
Second, following Host-Host protocol changes, the notion of message type is dropped from RJE and RJOR. They no longer send, or expect to receive, 8 bits of zeros as the first byte on a connection.
Third, RJE and RJOR now use a standard ICP (initial connection protocol) to create a full duplex connection to the user. They listen on sockets x'201' and x'301' instead of x'200' and x'300'. RJOR still calls the user back over a simplex connection to the user's receive socket when requested output is ready.
One service is closed because nobody used it. The job services get new mailbox numbers and stop sending a pointless first byte.
§3Byte Sizes
RJE/RJOR and SMFS specify a byte size of eight for their connection to the user's receive socket. The user may choose the byte size of the other simplex connection. UCSB accepts any valid byte size there.
On the connection that carries data to you, the pieces must be eight bits wide. On the other one you can pick the size you like.