RFC 50 UNKNOWN META · PROTOCOL

Comments on the Meyer Proposal

RAND Corporation's feedback supporting the Meyer proposal with some proposed modifications

On rfc-editor.org ↗
PUBLISHED
April 1970
AUTHORS
E. Harslen, J. Heafner
STREAM
Legacy
DOI
10.17487/RFC0050

RFC text

Original text · RFC Editor View on rfc-editor.org ↗
                                                  E. Harslen
                                                  J. Heafner
Network Working Group                             RANL
Request for Comments:    50                       4/30/70


                     Comments on the Meyer Proposal
                     ------------------------------

We find the Meyer proposal (Note #46) to be the most acceptable
to dare, for exactly the reasons that he enumerates; viz., simple,
suffices for most planned uses of the Network, easy to implement,
can be extended.  It does not encompass everything that has been
suggested recently, however, we do agree with the items that are
proposed and we feel that the missing features are probably not
worth doing battle over and thus delaying the specification.

We make the following comments on the seven issues rasied in
Note #47.

   1)  We agree with Steve that dynamic reconnection will later
       be required for more sophisticated uses of the Network.
       We also agree with the Project MAC people that it
       unnecessary initially.  A better job can be done of dynamic
       reconnection given some Network experience and the specific
       needs of its use.

   2)  INT is easy to implement and serves a useful purpose.

   3)  We favor including a sub-field for instance tag identifier.
       We see the need for both cases; a) where multiple processes
       should appear indistinguishable, and b) where a given
       user owning multiple processes must distinguish among
       them.  Those program parts that should not distinguish
       among processes should simply ignore the instance tag.
       Tom's suggestion to use part of the user number sub-field
       merely reduces the combined length of sub-fields from 32
       bits to 24 bits; the problem remains.

   4)  We disagree with both Steve and MAC in that no special
       structure should be imposed on the data transmitted.  We
       prefer the "message data type" mentioned by E. I. Ancona,
       Note #42, page 1.  An example of its use was cited in
       Note #39, page 2, transmit vs broadcast.

       With regard to a standard character set, we strongly
       support adopting one in the beginning, and in particular
       ASCII.  We have observed that most sites have previously
       suggested ASCII.  Is there anyone who objects?

   5)  Word boundary alignment is more attractive than double
       padding.

   6)  Steve's suggestion of short-term queueing of RFCs is
       acceptable as an option.

   7)  We support the UCC in Note #46 for three principle reasons:

       a)  In general the user should not know the remote socket
           code of the process to whom he wishes to communicate.

       b)  The additional duplex connection can provide some
           superfisory control over process behavior, possibly
           in conjunction with the interrupt procedure.

       c)  Most of the other proposed methods demand queueing.

      We think there must be a standard UCC, yet we encourage
      parallel experimental UCCs.

We make two additional comments on Note #46 that were not reiterated
in Note #47.

BLK and RSM are more straightforward than previous suggestions and
they do not deny multiplexing over a given link.  With regard to
the use of links, we refer to an example given by Bob Kahn where
an intermediate IMP goes down and eats some's RFNM.  This
should not necessitate reconnection.

In Note #46, page 6, the statement that the UCC has the ability
to close connections to a dead process is installation dependent.
In our particular case the NCP is notified directly of process
failure due to the particular software interface through which all
processea, including NCP, must communicate.


JFH:hs

       [ This RFC was put into machine readable form for entry ]
          [ into the online RFC archives by Gary Okada 7/97 ]

AI ELI5

On this page
PROBLEMThe Meyer proposal is more acceptable than previous complex proposals, but some design choices in RFC 46 and RFC 49 need clarification or modification.
MECHANISMHarslem and Heafner endorse the Meyer proposal's simplicity and extensibility. They support keeping dynamic reconnection for later, including the INT command, adding instance tags for process distinction, standardizing ASCII for teletype communication, and supporting the proposed UCC protocol for login.
DESIGN CONSENSUSThis feedback from RAND reinforces consensus on the basic protocol design, clearing the way for formal specification and implementation.

§1Support for Meyer's Approach

Harslem and Heafner from the RAND Corporation find the Meyer proposal to be the most acceptable proposal to date, precisely because it is simple, sufficient for planned network uses, easy to implement, and extensible. They recognize that it does not encompass every suggested feature, but they argue that the missing features are not worth delaying the specification. This perspective proves crucial: they validate the design philosophy that a good initial standard beats a perfect one that takes years to negotiate.

RAND agrees that Meyer's simple proposal is better than trying to include everything, even if some features are left out.

§2Agreed Design Decisions

Harslem and Heafner agree on several key points from the debate: dynamic reconnection should wait for later implementations (not in the initial protocol), the INT interrupt command is valuable and easy to implement, and they support including instance tags in socket identifiers to distinguish multiple processes. Notably, they support standardizing on a character set (ASCII is their preference, matching the IMP standard) for teletype-to-foreign-monitor communication. They endorse the UCC protocol proposal, noting that users should not need to know remote socket codes. They also prefer the BLK and RSM commands for flow control, which do not impede later multiplexing of sockets over a single link.

They agree on keeping the protocol simple now, adding features later, supporting INT commands, using ASCII for text, and having a standard login protocol.

§3Installation-Specific Implementation

The RFC includes a note that some design choices are installation-dependent. Specifically, they mention that UCC's ability to close connections of dead processes can vary depending on how each site's operating system notifies the NCP of process failures. At RAND, the NCP is notified directly through the software interface used by all processes. This acknowledgment shows the authors' understanding that different computer systems will implement the protocol differently, as long as the external behavior (the protocol itself) remains compatible.

Different computers might build the protocol differently on the inside, as long as the network connections work the same way.

§4References