Network Working Group H. Murray
Request for Comments: 415 Stanford Research Institute
NIC: 392 29 November 1972
TENEX BANDWIDTH
NIC 11584 (RFC 392) BY G. HICKS AND B. WESSLER AT UTAH RECENTLY
DISCUSSED THE COST OF USING THE NETWORK.
I WOULD LIKE TO TAKE THESE SAME TYPES OF NUMBERS AND LOOK AT THEM
FROM ANOTHER POINT OF VIEW. WITHOUT CALCULATING COSTS, LET US
CONSIDER ULTIMATE PERFORMANCE OF THE HOSTS. I WROTE A SIMPLE TENEX
PROGRAM THAT SENT ITSELF STRINGS OVER THE NET. IT USED BIN/BOUT AND
THE BUFFERED SEND MODE. IT COUNTED THINGS, BUT DID NOT PROCESS THE
STRING. WITH SAMPLES OF A MILLION BITS, THE FOLLOWING RESULTS WERE
OBTAINED.
BYTES/SIZE REAL BAUD CPU BAUD CPU NEEDED
50/36 48.8K 291K 16%
100/36 46.5K 309K 15%
200/36 52.7K 322K 16%
400/36 59.3K 267K 22%
800/36 61.1K 279K 21%
50/8 22.0K 70K 31%
100/8 26.7K 76K 35%
200/8 29.0K 79K 36%
400/8 30.0K 81K 37%
800/8 31.9K 78K 40%
1600/8 38.1K 64K 59%
3200/8 41.8K 59K 70%
THE FOLLOWING WERE OBTAINED BY USING SIN/SOUT WITHOUT THE BUFFERED
MODE.
BYTES/SIZE REAL BAUD CPU BAUD CPU NEEDED
50/36 36K 95K 38%
100/36 44K 95K 45%
200/36 49K 92K 53%
400/36 54K 90K 60%
50/8 12K 22K 57%
100/8 16K 21K 75%
200/8 18K 20K 92%
400/8 20K 20K 99%
THESE TESTS WERE RUN WITH NO OTHER LOAD ON OUR SYSTEM, AN EARLY
VERSION OF 1.29. THE INPUT AND OUTPUT HALVES OF THE TRANSMISSION
HAVE BEEN AVERAGED TOGETHER. I.E. THE ABOVE BAUD RATES WERE
CALCULATED USING 2 MILLION BITS SINCE THE STRINGS WENT OUT AND IN.
OTHER PIECES OF DATA:
OUR TTY'S AND LPT HAVE ULTIMATE CPU BANDWIDTHS NEAR 15-20 KB. AT
2400 BAUD, A TTY TAKES 15% OF THE CPU. TELNETS NESTED THREE DEEP ARE
ALMOST COMPUTE LIMITED WHEN JUST TYPING THINGS OUT ON A 2400 BAUD
TERMINAL.
AS A ROUGH CALCULATION, THE BANDWIDTH OF THE TIP TAPE TRANSMISSION
FEATURE - USING STEVE BUTTERFIELD'S (OF BBN) NETMAG PROGRAM - IS
ABOUT 7 KILOBITS/SEC. ONE TAPE OF ABOUT 6,000 TENEX PAGES TOOK ABOUT
4 HOURS TO TRANSMIT. THIS WAS A FULL TAPE FROM ETAC TO CCA LATE ONE
NIGHT WITH NOTHING ELSE RUNNING ON OUR SYSTEM. ABOUT 30% OF THE CPU
IS NEEDED TO MAINTAIN THIS BANDWIDTH. AGAIN THIS IS ONLY ABOUT 20KB
PER CPU SEC.
[This RFC was put into machine readable form for entry]
[into the online RFC archives by Helene Morin, Via Genie 12/99]
AI ELI5
On this page
§1Measuring Network Throughput
This note measures how fast a TENEX host can send data over ARPANET and how much CPU effort it requires. The author wrote a simple program that sent strings to itself, using either buffered or unbuffered I/O modes, and measured the throughput with samples of a million bits.
Someone tested how fast a computer could send data to itself across the network, counting both speed and effort.
§2Buffered Mode Results
Using buffered send mode with different byte sizes, real throughput ranges from 22 to 61 kilobits per second, with CPU usage from 15% to 40%. Larger byte sizes (400, 800 bytes) achieve better throughput (59-61 kilobits per second) using only 21-22% CPU. Smaller sizes (50-100 bytes) reach about 46-48 kilobits per second with 15-16% CPU. A larger configuration with 3200-byte blocks reaches 41.8 kilobits per second using 70% CPU.
Sending in bigger chunks is faster but uses more CPU. Small chunks are slower and less demanding.
§3Unbuffered Mode and System Limits
Without buffered mode, throughput drops significantly: from 36 to 54 kilobits per second with 36-bit sizes, using 38-60% CPU, and from 12 to 20 kilobits per second with 8-bit sizes, using up to 99% CPU. For comparison, local TTYs and line printers achieve about 15-20 kilobytes CPU bandwidth. At 2400 baud, a single TTY uses 15% of the CPU. Three nested Telnet sessions almost saturate the compute capacity when outputting to a 2400-baud terminal. Network tape transmission via the TIP achieves about 7 kilobits per second, using about 30% CPU.
Without buffering, the computer works much harder and goes slower. Local devices and nested network services can nearly use up all the CPU.